Single steel plant horizontal, vertical seismic calculation method What?
Plant lateral seismic calculation Normally, the roof should be included in the spatial deformation analysis; use light roof, the plane can be calculated bent frame. Guangzhou Steel
Plant longitudinal seismic calculation, the choice of the following methods:
Lightweight wallboard or wallboard plant and a large column of flexible connection, according to the single particle calculations, seismic columns each column should assign the following principles:
① reinforced concrete roof without purlins column column stiffness can share allocation;
② lightweight roof can withstand the share of pillar column gravity load representative value distribution;
③ reinforced concrete roof purlin desirable results above the average of the two distribution. Guangzhou Steel